Dry-Type SC(B)12-30~2500/10/0.4 Transformer

Home > Products > Dry-Type Transformer > Dry-Type SC(B)12-30~2500/10/0.4 Transformer

Dry-Type SC(B)12-30~2500/10/0.4 Transformer

  • Brand Hengda
  • Model No. SC(B)12-30~2500/10/0.4
  • Phase 3 Phases
  • Vector Group/Connection Type Yyn0 or Dyn11
  • Tap Ranger ±5% or ±2*2.5%
  • Frequency 50HZ/60HZ
  • Coil Material Copper/Aluminum
Get Free Quote


Resin insulated dry-type transformer, due to the coil is encapsulated by epoxy resin, so it is flame retardant, fireproof, explosion-proof, maintenance-free, non-polluting, small in size, and can be directly placed in the load center. Due to the scientific and reasonable design and casting process, the product has smaller partial discharge, low noise, strong heat dissipation ability, and can be operated for a long time under 125% of the rated load under the condition of forced air-cooling, and is equipped with a temperature controller, which has the functions of fault alarm, over-temperature alarm, over-temperature trip, and black-box function, and is connected to the computer through the RS485 serial interface to enable centralized monitoring and control.

Rated Power
(kVA)
Voltage Combination Vector Group/
Connection Method
No-Load Loss Load Loss Short-circuit Impedance No-load Current
H.V(kV) H.V. Tap Range(%) L.V(kV) W W % %
30 6
6.3
10
10.5
11
±5%
or±2*2.5%
0.4 Dyn11 150 710 4 2
50 215 1000 2
80 295 1380 1.5
100 320 1570 1.5
125 375 1850 1.3
160 430 2130 1.3
200 495 2530 1.1
250 575 2760 1.1
315 705 3470 1
400 785 3990 1
500 930 4880 1
630 1040 5960 6 0.85
800 1215 6960 0.85
1000 1415 8130 0.85
1250 1670 9690 0.85
1600 1960 11730 0.85
2000 2440 14450 0.7
2500 2880 17170 0.7
Operating Condition: 1.Altitude not exceeding 1000 meters
2.Maximum ambient temperature +40°C
3.Maximum daily average temperature +30°C
4.Maximum annual average temperature +20°C
5.Maximum low temperature-25°C
6.Transformers for operation under special conditions are available upon request.

 

Features:

Low-voltage winding: Low-voltage winding adopts foil structure, which solves the problem of axial helix angle when winding with wire and makes the ampere-turns more balanced, meanwhile, the coil adopts axial cooling duct to enhance the heat dissipation ability, and epoxy resin is adopted between the winding layers, and the whole is cured and shaped.

The core is made of imported high-quality cold-rolled silicon steel sheet, the core column is tied with F-class latitude-free tape, and the surface of the core is encapsulated with epoxy resin, which reduces the no-load loss, no-load current and noise of the core.

The clamps and fasteners are treated with special surface treatment, which further improves the product appearance quality.

Adopting cross-flow side-blowing cooling fan, the cooling fan has the characteristics of low noise, high wind pressure, beautiful appearance, etc., which enhances the overload capacity of the transformer. Temperature control adopts only temperature controller, which improves the reliability of transformer operation.

 